Mectron Blog

Ultrasonic implant site preparation using PIEZOSURGERY®: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

Home » Blog » PIEZOSURGERY® » Ultrasonic implant site preparation using PIEZOSURGERY®: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).

Vercellotti T, Stacchi C, Russo C, Rebaudi A, Vincenzi G, Pratella U, Baldi D, Mozzati M,
Monagheddu C,Sentineri R, Cuneo T, Di Alberti L, Carossa S, Schierano G.

Int J Periodontics Restorative Dent. 2014 Jan-Feb;34(1):11-8